Method to improve accuracy mass measurement fluid in the tank

Cover Page

Cite item

Full Text

Abstract

Considered two methods to improve the accuracy of measuring the mass of fluid in the tank based on the non-linear interpolation of the experimental calibration data. The first method is to find a transformation function mass and the total parameters of the fluid measured by monitoring with the help of the calibration model of the measurement process. The second method is based on the determination of an individual analytical dependence for the tank, connecting a lot of fluid, with its qualitative and quantitative parameters.

About the authors

A. V. Solntseva

Samara State Aerospace University

Author for correspondence.
Email: als063@mail.ru

Post-graduate Student

Russian Federation

B. V. Skvortsov

Samara State Aerospace University

Email: aps@ssau.ru

Doctor of Technical Science, Professor

Russian Federation

S. A. Borminsky

Samara State Aerospace University

Email: b80@mail.ru

Candidate of Technical Science, Docent

Russian Federation

References

  1. Скворцов, Б.В. Электрофизические устройства контроля качества углеводородных топлив [Текст] / Б. В. Скворцов. – Самара: Изд-во СГАУ, 2000. – 264 с.
  2. Скворцов, Б.В. Импульсные методы измерений количества и качества жидких углеводородных топлив [Текст] / Б.В. Скворцов, Борминский С. А. – Самара: Изд-во СНЦ РАН, 2010. – 220 с.